Page 51
Site requirements
Operating environment
Relative humidity: 20% to 80% non-condensing
Temperature: 60° F to 95° F (15° C to 35° C)
Electrical requirements
The power supply is rated at 100-240 VAC, 50-60 Hz, 5.4
amp. (It adjusts to any power within this range.)
Single phase, 3-wire, grounded receptacle only.
Physical requirements
The printer weighs less than 30 pounds (13.6 kg). The
weight depends on the supplies and options installed.
Printer dimensions are 23.1 inches (587 mm) long and 9.9
inches (251 mm) wide. With the 100-card input hopper, the
printer is 18.8 inches (478 mm) high and with the 200-card
hopper, it is 21.3 inches (541mm) high.
The clearance required 9.5 inches (241 mm) at the back, 2
inches (51 mm) on the left side, and 10.5 inches (267 mm)
above the printer latch to open the cover.